Frequently Asked Question Details :
Back

Title: About MS-850 Raster

Description: Details on how to turn raster option on and off

Issue: How does the raster on/off feature work on the MS-850?

Solution: The MS-850 raster on/off feature works with the laser on/off feature. To enable raster on/off, first enable laser on/off. In ESP, click on menu, then output. Check the box that says Laser on/off. Click apply and send/save. (Note: make sure you receive from scanner before you send/save). Next, click on the raster set up button. Locate and check the box "read cycle on/off" then apply. You will also need to be in a triggered mode other than continuous or continuous 1 for the mode to work.

Other Keywords:

Print this FAQ


Back